8.5.10.1. Removal of a bolt of the obgonny coupling
Fig. 8.70. Removal of a bolt of the obgonny coupling
|
At removal and installation of a bolt hold press a disk, as shown in the figure 8.70.
At installation of the new compressor of the air conditioning system replace a bolt.
Fig. 8.71. Removal of sealant from the compressor
|
After removal of the stator and the device of thermal protection completely remove sealant from the compressor of the air conditioning system (fig. 8.71).
Before installation apply about 1 g of silicone sealant (KE-347W sealant or similar) on the contact surface of the device of thermal protection, then accurately install it on the compressor air conditioning systems, without leaving gaps.
At installation of the new stator and device of thermal protection, replace the screw.
At installation of the new stator and device of thermal protection, replace a collar.
Fig. 8.72. Scheme of replacement of a lock ring
|
At installation of a new press disk, pulley of the compressor of the air conditioning system, stator or case of the compressor replace a lock ring (fig. 8.72).