2.13.3. Removal and installation of the sensor of provision of a butterfly valve
Uncover the rechargeable battery.
Disconnect a negative wire from the rechargeable battery.
Perform the following procedure for ensuring convenience of access.
Remove the air filter.
Remove an air hose.
Fig. 2.343. Removal of the sensor of provision of a butterfly valve
|
Remove the sensor of provision of a butterfly valve (fig. 2.343).
Make sure that the butterfly valve is completely closed.
Install the sensor of provision of a butterfly valve on a throttle branch pipe.
Inhaling moment: 1,6–2,4 N · m.
Make sure that the butterfly valve moves smoothly.
Connect the socket of the sensor of provision of a butterfly valve.
Make sure that tension of an output signal of the sensor of provision of a butterfly valve (PID WDS: the provision of a butterfly valve) – within norm when the gate is open or closed.
If does not meet standard, check the sensor of provision of a butterfly valve.