2.3.3.1. Fuel leak check
Disconnect a negative wire of the rechargeable battery.
Remove fuel nozzles together with the fuel distributor, without disconnecting a fuel supply hose.
Fig. 2.219. The distributor of fuel and fuel nozzles fixed by a wire
|
Rigidly fix fuel nozzles in the fuel distributor by means of a wire (fig. 2.219).
Connect a negative wire of the rechargeable battery.
Fig. 2.220. The scheme of connection of a conclusion of the control F/P socket with a mass of a body of GND by means of a crossing point
|
Connect a conclusion of the control F/P socket to the mass of a body of GND by means of a crossing point (fig. 2.220).
Turn the ignition key in position of ON to turn on the fuel pump.
Fig. 2.221. Tilt angle of fuel nozzles
|
Incline fuel nozzles approximately by 60 degrees (fig. 2.221).
Check leak of fuel from snuffled fuel nozzles. If the size of leak exceeds norm, replace a fuel nozzle.
Normal leak of fuel – less than 1 drop in 2 min.
Turn the ignition key in position of LOCK and remove a crossing point.
Install the fuel distributor into place.