d22f196b

2.3.3.2. Check of productivity

NOTE
If at your disposal there is no special tester of fuel nozzles, execute "The test of leak of fuel" to check serviceability of a fuel nozzle.

Disconnect a negative wire of the rechargeable battery.
Remove fuel nozzles.
Connect a fuel nozzle to the tester of fuel nozzles.
Measure the volume of the fuel injected each fuel nozzle, using the graduated container. If the size of leak exceeds norm, replace a fuel nozzle.
Volume of injectable fuel:
L3: 61–71 ml/15 with;
LF: 53–69 ml/15 with;
L8: 48–63 ml of/15 pages.
Turn the ignition key in position of LOCK and remove a crossing point.
Establish nozzles into place.