d22f196b

3.3.4.7. Adjustment of the switch of range of the transmission

Disconnect a wire from the negative plug of the rechargeable battery.

Fig. 3.82. Detachment of a cable of control of the transmission


Turn off a nut and disconnect a cable of control of the transmission (fig. 3.82).

Fig. 3.83. Installation of a shaft of the switch of prohibition of start in situation N


Establish a shaft of the switch of prohibition of start in situation N, as shown in the figure 3.83.

Fig. 3.84. Start prohibition switch socket detachment


Disconnect the socket of the switch of prohibition of start (fig. 3.84).

Fig. 3.85. Bolts of fastening of the switch of prohibition of start


Weaken bolts of fastening of the switch of prohibition of start (fig. 3.85).

Fig. 3.86. Start prohibition switch socket


Connect an ohmmeter to conclusions In and From the socket of the switch of prohibition of start (fig. 3.86).
Turning the start prohibition switch, define situation at which there is a conductivity between socket conclusions.
Nominal indication of value of an ohmmeter: 750 Ohms.
Tighten bolts of fastening of the switch of prohibition of start.
Inhaling moment: 8–11 N · m.
Make sure that position of the selector corresponds to position of the switch of prohibition of start.
Connect the start prohibition switch socket.

Fig. 3.87. Installation of a clamp of a cable of control of the transmission


Establish a clamp of a cable of control of the transmission, as shown in the figure 3.87.
Tighten a nut of fastening of a cable of control of the transmission and adjust its situation.
Establish a clamp and a cable of control of the transmission.
Connect the negative plug of the rechargeable battery.