d22f196b

2.2.10.10. Installation of a cover of a head of the block of cylinders

Fig. 2.114. Places of putting sealant


Apply kremniyevoorganichesky sealant on the interfaced surfaces of the block of cylinders in the places shown by shooters (fig. 2.114).
Diameter of a point of drawing – 4,0–6,0 mm.
Establish a cover of a head of the block of cylinders with new laying.

Fig. 2.115. Order of tightening of bolts of fastening of a cover of a head of the block of cylinders


Tighten fastening bolts in the order specified in the figure 2.115, the moment of an inhaling of 8-11,5 N · m.