2.2.15.7. A press fitting of the directing valve plug
Fig. 2.146. A press fitting of the directing valve plug: 1 – the directing valve plug
|
Press the directing valve plug from outside, opposite to a cam-shaft, against the stop special adaptation in a head of the block of cylinders (fig. 2.146).
Fig. 2.143. The measured height: 1 – naprvlyayushchy plug of the valve; 2 – head of the block of cylinders
|
Make sure that height of a projection of the directing valve plug (size A) meets standard (see fig. 2.143).
Standard height:
- Admission: 12,2–12,8 mm;
- Release: 12,2–12,8 mm.